Manvac 3phase Water Inverter Pump High-Efficiency Debugging with DC Voltage

Product Details
Customization: Available
Application: High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer
Output Type: Triple
Still deciding? Get samples of US$ 99/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2016

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Low MOQ
The MOQ for the supplier's products is 1
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (15)
  • Manvac 3phase Water Inverter Pump High-Efficiency Debugging with DC Voltage
  • Manvac 3phase Water Inverter Pump High-Efficiency Debugging with DC Voltage
  • Manvac 3phase Water Inverter Pump High-Efficiency Debugging with DC Voltage
  • Manvac 3phase Water Inverter Pump High-Efficiency Debugging with DC Voltage
  • Manvac 3phase Water Inverter Pump High-Efficiency Debugging with DC Voltage
  • Manvac 3phase Water Inverter Pump High-Efficiency Debugging with DC Voltage
Find Similar Products

Basic Info.

Model NO.
VM1000B-2TR75GB
Switch Mode
High Carrier Frequency PWM Control
Main Circuit Type
Voltage
Voltage of Power Supply
High Voltage Variable-Frequency Drive
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
Voltage Variable-Frequency Drive
Function
Three Types;Linear,Multipoint,Square V/F Curve
Brand
Manvac
Starting Torque
0.5Hz/100%
Speed Holding Precision
±1%
Output Current
3.8A
Output Frequency
0-400Hz
Certificate
TUV CE
Transport Package
Carton
Specification
88*138*187
Trademark
MANVAC
Origin
Guangdong
HS Code
85177010
Production Capacity
500000pieces/Year

Packaging & Delivery

Package Size
24.00cm * 29.00cm * 34.00cm
Package Gross Weight
24.000kg

Product Description

Product Overview
Manvac 3phase Water Inverter Pump High-Efficiency Debugging with DC Voltage
 
FEATURES AT A GLANCE Manvac 3phase Water Inverter Pump High-Efficiency Debugging with DC Voltage
Manvac 3phase Water Inverter Pump High-Efficiency Debugging with DC Voltage
Manvac 3phase Water Inverter Pump High-Efficiency Debugging with DC Voltage
Manvac 3phase Water Inverter Pump High-Efficiency Debugging with DC Voltage
 
PRODUCT SPECIFICATIONS
Item
Description
Control
Characteristics
Control Mode
Sensorless vector control (SVC)
V/F Control
V/F Control
0.5Hz/150%
0.5Hz/100%
Speed Adjustment Range
1:100
1:50
Speed Holding Precision
±0.5%
±1%
Carrier Frequency
0.5kHz ~ 16kHz;The carrier frequency can be
automatically adjusted according to the load characteristics
Overload Capacity
G type: 150% rated current for 60s; 180% rated current for 1s
P type: 120% rated current for 60s; 150% rated current for 1s
Torque Compensation
Automatic: 0.0%; Manual : 0.1%-30.0%
Operation
Control
Input Voltage Range
220V/380V;fluctuation range:±15%
Input Frequency Range
50/60Hz;fluctuation range:±5%
Output Voltage Range
0- input voltage,Error limit 5%
Output Frequency Range
SVC:0-320Hz;V/F:0-1000Hz
Command Running Channel
Three kinds of channels: 1. Operation keyboard 2.Control terminal 3.Serial communication port, switchable by many ways
Frequency Source
Digital setting, Potentiometer of operation board, Analog Voltage Signal,
Analog Current Signal, Communication port settin, switchable by many ways
Auxiliary Frequency Source
Multiple auxiliary frequency source, capable of frequency synthesis and frequency trimming
Input Terminals
6 Digital Input Terminals 2 Analot Input Terminals
Output Terminals
1 Open Collector Output Terminals;2 Relay Output Terminals
2 Analog Output Terminals(Model with a power of less than 7.5kW only have one)
Basic Functions
DC Braking
Braking time:0.0s ~ 100.0s,Braking current value:0.0% ~ 100.0%
V/F Curve
Three types:linear, multipoint, square V/F curve
Acceleration and
Deceleration Curve
Linear mode and S curve acceleration and deceleration mode; 4 groups of acceleration
and deceleration time; the range of acceleration and deceleration time0.0~6500.0S
Simple PLC, Multi-speed Control
Linear mode and S curve acceleration and deceleration mode; 4 groups of acceleration
and deceleration time; the range of acceleration and deceleration time0.0~6500.0S
Integrated PID
Closed-loop control system
AVR Function
When grid voltage changes, it keeps output voltage constant automatically
Control of Overvoltage,
Overcurrent, Speed Stall
The current and voltage are limited automatically during the running
process so as to avoid frequent tripping due to overvoltage/overcurrent
Rapid Current Limit
Decrease overcurrent at max, protect VFD to operate regularly
Torque Limit and Control
Limit the torque automatically and prevent frequent over current
trippingduring the running process
Power peripheral and
Safety Self-checking
To realize self checking of peripheral equipment at power on, such as
grounding fault, short circuit fault, etc
Timing Control
Timing control range:0h~65535h
Protection Functions
Motor short-circuit detection at power-on, input/output phase loss protection,
overcurrent protection, overvoltage protection, undervoltage protection,
overheat protection and overload protection etc
Display and
Panel Operation
LED Display
5 bits LED Display
Parameter Lock
Define whether the parameter is locked in running or stopped state in case of misoperation
MF.K Key
Programmable: Command channel switching / forward rotation and reverse
rotation / JOG function selection / menu mode switching
Application
Environment
 
Operation Place
Indoor, free from direct sunlight, no dust, no corrosive gas, no combustible
gas, no oil smoke, no vapor, no drip or salt.
Altitude
Lower than 1000m. Service in derated capacity when above 1000m. Derate
1% capacity every 100m increase in height.
Ambient Temperature
-10°C~+40°C,A33Service in derated capacity when temperature higher than 40ºC. Derate 1%
capacity every 1ºC increase in temperature.And the maximum environmental temperature is 50 ºC.
Humidity
≤ 95%RH, no water condensatainon
Vibration
< 5.9m/s² (0.6G)
Storage Temperature
-25ºC~ +60ºC
 
Product Application

Manvac 3phase Water Inverter Pump High-Efficiency Debugging with DC Voltage
Our Factory
Manvac 3phase Water Inverter Pump High-Efficiency Debugging with DC Voltage
Manvac 3phase Water Inverter Pump High-Efficiency Debugging with DC Voltage
Manvac 3phase Water Inverter Pump High-Efficiency Debugging with DC Voltage
 
Manvac 3phase Water Inverter Pump High-Efficiency Debugging with DC Voltage
Manvac 3phase Water Inverter Pump High-Efficiency Debugging with DC Voltage
SIMILAR PRODUCTS
 
Manvac 3phase Water Inverter Pump High-Efficiency Debugging with DC Voltage
 
FAQ
1. What is the warranty of your machine?
R: 1 years, any product itself question,you can contact with us.
2. What is the material of your machine , is oil free?
R: our machine is aluminum alloy, motor is 100% copper coil , of course, we are oil free.
3. How to operate your machine?
R: Connect with wire, and turn on the power, so you can use it directly, about the wiring method, we will tell you how to do
according to your voltage, so at first , you need to tell us your voltage and phase,its important.
4. You are trading company or manufacture?
R: We are manufacture, we can provide long-term supply with fast speed.
5. How to contact with you?
R: You can send messages to me directly by alibaba trade manager, or add me like below

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now