Customization: | Available |
---|---|
Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer |
Output Type: | Triple |
Still deciding? Get samples of US$ 99/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Item
|
Description
|
||
Control
Characteristics
|
Control Mode
|
Sensorless vector control (SVC)
|
V/F Control
|
V/F Control
|
0.5Hz/150%
|
0.5Hz/100%
|
|
Speed Adjustment Range
|
1:100
|
1:50
|
|
Speed Holding Precision
|
±0.5%
|
±1%
|
|
Carrier Frequency
|
0.5kHz ~ 16kHz;The carrier frequency can be
automatically adjusted according to the load characteristics
|
||
Overload Capacity
|
G type: 150% rated current for 60s; 180% rated current for 1s
P type: 120% rated current for 60s; 150% rated current for 1s
|
||
Torque Compensation
|
Automatic: 0.0%; Manual : 0.1%-30.0%
|
||
Operation
Control
|
Input Voltage Range
|
220V/380V;fluctuation range:±15%
|
|
Input Frequency Range
|
50/60Hz;fluctuation range:±5%
|
||
Output Voltage Range
|
0- input voltage,Error limit 5%
|
||
Output Frequency Range
|
SVC:0-320Hz;V/F:0-1000Hz
|
||
Command Running Channel
|
Three kinds of channels: 1. Operation keyboard 2.Control terminal 3.Serial communication port, switchable by many ways
|
||
Frequency Source
|
Digital setting, Potentiometer of operation board, Analog Voltage Signal,
Analog Current Signal, Communication port settin, switchable by many ways
|
||
Auxiliary Frequency Source
|
Multiple auxiliary frequency source, capable of frequency synthesis and frequency trimming
|
||
Input Terminals
|
6 Digital Input Terminals 2 Analot Input Terminals
|
||
Output Terminals
|
1 Open Collector Output Terminals;2 Relay Output Terminals
2 Analog Output Terminals(Model with a power of less than 7.5kW only have one)
|
||
Basic Functions
|
DC Braking
|
Braking time:0.0s ~ 100.0s,Braking current value:0.0% ~ 100.0%
|
|
V/F Curve
|
Three types:linear, multipoint, square V/F curve
|
||
Acceleration and
Deceleration Curve
|
Linear mode and S curve acceleration and deceleration mode; 4 groups of acceleration
and deceleration time; the range of acceleration and deceleration time0.0~6500.0S
|
||
Simple PLC, Multi-speed Control
|
Linear mode and S curve acceleration and deceleration mode; 4 groups of acceleration
and deceleration time; the range of acceleration and deceleration time0.0~6500.0S
|
||
Integrated PID
|
Closed-loop control system
|
||
AVR Function
|
When grid voltage changes, it keeps output voltage constant automatically
|
||
Control of Overvoltage,
Overcurrent, Speed Stall
|
The current and voltage are limited automatically during the running
process so as to avoid frequent tripping due to overvoltage/overcurrent
|
||
Rapid Current Limit
|
Decrease overcurrent at max, protect VFD to operate regularly
|
||
Torque Limit and Control
|
Limit the torque automatically and prevent frequent over current
trippingduring the running process
|
||
Power peripheral and
Safety Self-checking
|
To realize self checking of peripheral equipment at power on, such as
grounding fault, short circuit fault, etc
|
||
Timing Control
|
Timing control range:0h~65535h
|
||
Protection Functions
|
Motor short-circuit detection at power-on, input/output phase loss protection,
overcurrent protection, overvoltage protection, undervoltage protection,
overheat protection and overload protection etc
|
||
Display and
Panel Operation
|
LED Display
|
5 bits LED Display
|
|
Parameter Lock
|
Define whether the parameter is locked in running or stopped state in case of misoperation
|
||
MF.K Key
|
Programmable: Command channel switching / forward rotation and reverse
rotation / JOG function selection / menu mode switching
|
||
Application
Environment
|
Operation Place
|
Indoor, free from direct sunlight, no dust, no corrosive gas, no combustible
gas, no oil smoke, no vapor, no drip or salt.
|
|
Altitude
|
Lower than 1000m. Service in derated capacity when above 1000m. Derate
1% capacity every 100m increase in height.
|
||
Ambient Temperature
|
-10°C~+40°C,A33Service in derated capacity when temperature higher than 40ºC. Derate 1%
capacity every 1ºC increase in temperature.And the maximum environmental temperature is 50 ºC.
|
||
Humidity
|
≤ 95%RH, no water condensatainon
|
||
Vibration
|
< 5.9m/s² (0.6G)
|
||
Storage Temperature
|